Seite 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL(M017B01-03-15A)Multifunctional energy meterCEM-C30CEM-C30 MID

Seite 2

3.4.- CONNECTION DIAGRAML1L2L3NS2 S1P2P1S2 S1P2P1S2 S1P2P1LOADPowerSupplyFigure 2: Connection diagram, CEM-C30�10CEM-C30Instruction Manual

Seite 3

3.5.- CONNECTIONSThe CEM-C30 has terminal covers to cover the top of the terminal box and the xing screws (Figure 3).Figure 3: Terminal covers

Seite 4 - CONTENTS

When the unit is connected to the mains, attach the safety label (Figure 5) to terminals 13 and 14, in order to prevent the risk of electric shock cau

Seite 5 - REVISION LOG

4�- OPERATION The CEM-C30 is an energy meter capable of measuring:  Imported and exported active energy and reactive energy in the four quadrants.

Seite 6

4.2.- DISPLAYThe unit has an LCD where all parameters are displayed.The display is divided into three areas (Figure 7):Figure 7: CEM-C30 Displa

Seite 7

4.3.- LED INDICATORSThe unit has two verication LEDs:  To verify the active energy�  To verify the reactive energy (according to version)

Seite 8

4.4.- DISPLAY MODES:The CEM-C30 has 2 display modes:  Display in standby mode  Display in reading mode 4�4�1� DISPLAY IN STANDBY MODEWith

Seite 9

Table 6 ( Continuation ) : Standby mode displaysScreen Parameters Reactive energy quadrant C+ total(1)(1) Only displayed if the reactive energy displ

Seite 10 - 3.4.- CONNECTION DIAGRAM

4�4�2� DISPLAY IN READING MODEThe reading mode is activated by a long press on the button.In reading mode you can:  View the voltage, current, acti

Seite 11 - Instruction Manual

4.5.- INSTANTANEOUS VALUE DISPLAYTo open the screens where the instantaneous value are viewed, long press the key on the display in standby mo

Seite 12 - 13 14

2CEM-C30Instruction Manual

Seite 13 - Figure 6: Sealing the button�

Table 7 ( Continuation ) : Instantaneous value screensScreen Parameters L3 CurrentActive three-phase powerReactive three-phase power(1)Apparent three

Seite 14

4.6.- PARTIAL ENERGY DISPLAYNB: The partial energy display menu is only displayed if the partial energy display option has been selected in the

Seite 15

Table 8 ( Continuation ) : Partial energy screens�Screen Parameters Partial reactive energy, quadrant 3 (C -) (1)Only displayed in the 4-quadrant ver

Seite 16

4.7.- CONFIGURATIONIn the setup menu you can:  Program the weight and type of impulse output  Program the communications.  Program the di

Seite 17

Figure 13: Validation screen�After a few seconds viewing the screen shown on Figure 13 , the system returns to the Impulse output weight programming m

Seite 18 - Figure 9:

To write or modify the value, short press the button repeatedly, increasing the value of the ashing digit.When the desired value is show

Seite 19

4�7�5� Type of communications NB: This is only displayed if there is a CEM M-RS485 (communications interface for the CEM family of units) connected t

Seite 20

Long press to view the options. The possible options are:Yes, if you want to view the partial energy.No, if you select this option, the unit

Seite 21

The possible options are:Yes, if you want a display view of the efciency screens (cost of energy and CO2 emissions).No, if you select this option,

Seite 22

4�7�8� Energy costNB: It is only displayed if the efciency factors display has been selected. This is the home screen for entering the energy cost p

Seite 23 - Figure 12:

SAFETY PRECAUTIONS DISCLAIMERCIRCUTOR, SA reserves the right to make modi cations to the device or the unit speci ca-tions set out in this instruct

Seite 24 - Figure 13: Validation screen�

To write or modify the value, short press the button repeatedly, increasing the value of the ashing digit.When the desired value is show

Seite 25

4.8.- MANUFACTURER INFORMATION SCREENLong press the button in the standby mode screen to open these display screens. Short press the button

Seite 26

Table 9 ( Continuation ) : Manufacturer information screens�Screen Parameters Reactive energy with resolution varh 32-bit CRC(1) The screen is displ

Seite 27

To validate the data, move to the last digit and long press the button; the validation screen will appear (Figure 15) indicating that the setup valu

Seite 28 - On : Backlight always ON

4�9�3� Current primary transformation ratio This is the home screen for entering the current primary ratio.Long press the button to view the value t

Seite 29

After a few seconds viewing the screen shown on Figure 15 , the system returns to the main screen of the Secondary current transformation ratio.4�9�5�

Seite 30

5�- TECHNICAL FEATURESPower supplyMode AuxiliaryRated voltage 230 V ~Tolerance ± 20 %Frequency 50...60Hz Consumption< 2 W< 10VA (In, Vref (with

Seite 31

( Continuation ) Impulse outputProgrammed weight of the impulse 10 Wh / impulseNo� of maximum impulses per second 12IR port (service port)Hardware EN6

Seite 32

StandardsElectrical energy metering equipment (AC)� Part 1: General require-ments, tests and test conditions� Metering equipment (indexes of class-es

Seite 33 - Figure 15: Validation screen�

6�- MAINTENANCE AND TECHNICAL SERVICE 7�- GUARANTEE• No returns will be accepted and no unit will be repaired or replaced if it is not ac-companied b

Seite 34

CONTENTSSAFETY PRECAUTIONS ��������������������������������������������������������������������������������������������������������������������������

Seite 35

8�- CE CERTIFICATE40CEM-C30Instruction Manual

Seite 36 - 5�- TECHNICAL FEATURES

41Instruction ManualCEM-C30

Seite 37

CIRCUTOR, SA Vial Sant Jordi, s/n08232 -Viladecavalls (Barcelona)Tel.: (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 www.circutor.es central@circutor

Seite 38 -

REVISION LOGTable 1: Revision log�Date Revision Description07/14 M017B01-03-14A Initial Version11/14 M017B01-03-14BChanges in the following sections:

Seite 39

1�- VERIFICATION UPON RECEPTIONCheck the following points upon receiving the unit: a) The unit meets the specications described in your order. b)

Seite 40 - 8�- CE CERTIFICATE

The CEM-C30 is offered in different versions; Table 2 shows all of the possible options of the unit.Table 2: Options of the CEM-C30�Options CEM-C30 Co

Seite 41

3�- UNIT INSTALLATION 3.1.- PRELIMINARY RECOMMENDATIONSIn order to use the unit safely, it is critical that individuals who handle it follow th

Seite 42 - Vial Sant Jordi, s/n

3.2.- INSTALLATIONOn the side of the unit are all of the indications adjusted to the CEI 62052-11 standard.The unit is installed on a DIN rail.