The value placed In two successive
16-bit registers. These registers include
the same data as 32-bit registers from
the area 7500
The value is placed in 32-bit registers
Name
Write
(w)
/readout
(r)
Unit Name of the quantity
7000 7500 Identifier O
Constant identifying the device.
The value 183 means the DHB-4xx
meter
7002 7501 Status O
Status is register describing the current
state of the meter
7004 7502 Control O %
It is a register defining the control of the
analog output
7006 7503 Minimum O
Minimal value of the currently displayed
value
7008 7504 Maximum O
Maximal value of the currently
displayed value
7010 7505
Displayed
value
O Currently displayed value
7012 7506 Current time O Current time
7014 7507
Wire
resistance
O
W
Password of analog-to-digital
transducer
7016 7508 ADC O
Słowo przetwornika analogowo-cy-
frowego
7018 7509
Terminal
temperature
O
°C
Temperature of terminals – the mea-
surement is only carried out during the
temperature measurement by means of
thermoelectric sensors or during time
measurements
6.6. Registers Only for Readout
Table 11