Circutor DHB Series Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Circutor DHB Series herunter. CIRCUTOR DHB Series User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - INSTRUCTION MANUAL

DHB-402DHB-424INSTRUCTION MANUALProcess, temperature and resistor indicator signal(M045B01-03-14A)

Seite 2

104.2. Examples of ConnectionsAn example of the DHB-4xx meter connection to different signals is presented on the fig. 5.Fig. 5. Ways of the meter

Seite 3 - Contents

115. SERVICE5.1. Display DescriptionFig. 6. Description of the Meter Frontal Plate5.2. Messages after Switching the Supply onAfter switching the supp

Seite 4

125.3. Functions of Buttons - Acceptation button:Þ entry in programming mode (hold down ca 3 seconds) Þ moving through the menu – choice of level,Þ

Seite 5

13The pressure of the button combination and holding them down ca 3 seconds, causes the reset of alarm signaling. This operation acts only when t

Seite 6 - 2. METER SET

14Fig. 7. Service Algorithm of the DHB-4xx Meter

Seite 7 - DHB-424AL SAFETY

155.4. ProgrammingThe pressure of the button and holding it down through ca 3 seconds causes the entry to the programming matrix. If the entry is p

Seite 8 - 4. INSTALLATION

16Fig. 8. Programming Matrix.

Seite 9 - 4.1. Lead-out of Signals

17Table 15.4.2. Changing Floating-Point ValuesThe change is carried out in two stages (the transition to the next stage follows after pressing the

Seite 10 - 4.2. Examples of Connections

18Table 2IndParameter symbolDescription Range of changesIndCpNumber of points of the individual characteristic. For a value lower than 2, the individ

Seite 11 - 5. SERVICE

19dISPParameter symbolDescription Range of changesd_PMinimal position of the decimal pointWhen displaying the measured value - display format. This p

Seite 13

20tYP1tYP2tYP3tYP4Alarm type. Fig. 11 presents the graphical imaging of alarm typesn-on – normal (transition from 0 na 1),n-oFF – normal (transition f

Seite 14

21LEd1LEd2LEd3LEd4Support of alarm signaling. In the situation when the support function is switched on, After the alarm state retrea, the signaling d

Seite 15 - 5.4. Programming

22bAudBaud rate of the RS485 interface4.8 – 4800 bit/s9.6 – 9600 bit/s19.2 – 19200 bit/s38.4 – 38400 bit/s57.6 – 57600 bit/s115.2 – 115200 bit/sprotTy

Seite 16 - Fig. 8. Programming Matrix

23tEStDisplay test. The test consists in a successive lighting up of digital display segments. Alarm diodes and unit highlighting diodes should be li

Seite 17

24Rys. 10. Individual Characteristic.During the function approximation, one must remember that for the ap-proximation of functions strongly differing

Seite 18

25ged in the increasing sequence, such to preserve the following depen-dence:H1<H2<H3...<Hn If the above is not fulfilled, the individual cha

Seite 19

26Caution !l In case of alarms of n-on, n-off, on, off types the write of PrL>PrH will cause the alarm switching off. l In case of a measuring r

Seite 20

27Parametru symbol Level in the matrixStandard valuetYP1 1Pt1Con 1 0Cnt1 1 1indCP 2 noH0 2 0Y0 2 0H1 2 100Y1 2 100... ... ...Hn 2 (n-1)*100Yn 2 (n-1)*

Seite 21

28PrH1, PrH2, PrH3, PrH44, 5, 6, 7 2000dLY1, dLY2, dLY3, dLY4,4, 5, 6, 7 0LEd1, LEd2, LEd3, LEd44, 5, 6, 7 oFFP_An 8 InP1tYPA 8 0_10UAnL 8 0AnH 8 9

Seite 22

29Fig. 12. Connection Way of the RS-485 interfaceconnection of a higher quantity of devices, it is necessary to apply ad-ditional intermediate-separa

Seite 23

3Contents 1. APPLICATION AND METER DESIGN ...5 2. METER SET ...

Seite 24

306.2. Description of the MODBUS Protocol ImplementationThe implemented protocol is in accordance with the PI-MBUS-300 Rev G of Modicon Compa

Seite 25

316.4 Register mapThe register map of the DHB-424 meter is presented belowNotice: All given addresses are physical addresses. In some computer pro-gr

Seite 26

326.5. Registers for Write and ReadoutTable 9The value is placed in 16-bit registerswrite (w)/readout (r)Input type4000tYP1w/r 0...14Range Descriptio

Seite 27

33Value 0 0.0000 1 00.000 2 000.00 3 0000.0 4 000004008IndCpw/r 1...21Number of points of the individual characteristic. For the value 1, the ind

Seite 28 - 6. INTERFACE RS-485

34Support of alarm 1 signaling4016LEd1w/r 0...1Value 0 Support switched off 1 Support switched onDescriptionDescriptionValue 0 Main input 1 clo

Seite 29

35Value 0 n-on 1 n-off 2 on 3 off 4 h-on 5 h-offType of alarm 3 (description – fig. 6)Description4022tyP3w/r 0...5Delay of alarm 3 (in seconds)4

Seite 30 - Implementation

36Type of analog output4030tYPaw/r 0...2Value 0 voltage input 0...10 V 1 current input 0...20 mA 2 current input 4...20 mADescriptionBaud rate40

Seite 31 - 6.4 Register map

37 Bit 15 Break of the supply Bit 14 Re-set of the RTC clockSwitch on/off the unit highlight4038unitw/r 0, 1Value 0 highlight swiched off 1 hi

Seite 32

38Table 10 Bit 7 LED4 – Signaling of alarm nr 4. Bit 6 LED3 – Signaling of alarm nr 3. Bit 5 LED2 – Signaling of alarm nr 2. Bit 4 LED1 – Sign

Seite 33

397222 7611PrH 4w/r -19999...99999 Upper threshold of alarm 47224 7612AnL w/r -19999...99999 Lower threshold of analog output7226 7613AnH w/r -19999..

Seite 35

407278 7639Y9w/r -19999...99999 Expected value for the point nr 97280 7640H10w/r -19999...99999Point of the individual characteristic.Point nr 107282

Seite 36

41The value placed In two successive 16-bit registers. These registers include the same data as 32-bit registers from the area 7500The value is plac

Seite 37

427020 7510Measured valueOMeasured value - not recalculatedin relation to the individual character-istic, a.s.l.7022 7511 EMF OmVEMF measured on mete

Seite 38 - Table 10

437. ERROR CODESAfter switching the meter to the network or during the work, messages about errors can appear.Messages about errors and their reasons

Seite 39

448. TECHNICAL DATAMeasuring rangesTable 13Kind of input Indication range ClassPt100-205...855°C (-200...850°C)0.1Pt500Pt1000400 W 0...410 W (0...40

Seite 40

45Relay outputs - relays, NOC voltageless contacts load capacity 250 V~/0.5A~ - relays, switched voltageless contacts load capacity 250 V~

Seite 41 - Table 11

46Standards fulfilled by the meter:Electromagnetic compatibility:l noise immunity acc. to EN 61000-6-2l noise emissions acc. to EN 61000-6-4Safety r

Seite 42

479. MAINTENANCE AND TECHNICAL SERVICEIn the case of any query in relation to unit operation or malfunction, please contact the CIRCUTOR, SA Technical

Seite 43 - 7. ERROR CODES

4810. GUARANTEECIRCUTOR guarantees its products against any manufacturing defect for two years after the delivery of the units. • No returns will be

Seite 45

51. APPLICATION AND METER DESIGNThe DHB-4xx meter is a programmable digital panel meter destined for measurements of signals originating from standard

Seite 46

50CIRCUTOR, SA Vial Sant Jordi, s/n08232 -Viladecavalls (Barcelona)Tel.: (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 www.circutor.es central@circu

Seite 47 - 9. MAINTENANCE AND TECHNICAL

62. METER SETThe set is composed of: - DHB-4xx meter ...1 pc - User’s manual ...

Seite 48 - 10. GUARANTEE

73. BASIC REQUIREMENTS, DHB-424AL SAFETYIn the safety service scope, the DHB-4xx meter meets the requirements of the EN 61010-1 standard.Mentio

Seite 49

8Fig. 3. Overall DimensionsFig. 2. Meter Fixing4. INSTALLATIONThe meter has separable strips with screw terminals, which enable the connection of e

Seite 50 - Vial Sant Jordi, s/n

94.1. Lead-out of SignalsSignals led out on the meter connectors are presented on the fig. 4. Circuits of successive groups of signals are separated b