47
CVM
k
2
CONFIGURATION
4.7.2 - 8 DIGITAL INPUTS AND 4 RELAY OUTPUTS
To access the conguration of the card with 8 digital inputs and 4 relay outputs, enter the
conguration menu (menu ---> setup.) and in the EXP. CARDS menu, select the position where
the card is inserted.
To modify the card conguration parameters, press the EDIT button (F4).
Read Section 4.7.0., Inserting
Expansion Cards.
The parameters congured on the alarms screen have different meanings depending on the
electric variable chosen on the conguration line, Var. Code, (See Chapter 8.3, Modbus Memory
Map, to see the codes for all variables.)
Two types of electric variables are distinguished to congure an alarm.
- One real time value that is measured or calculated by the analyzer. (type a).
- Assigned an output for impulses (kW·h). One example of this type of variable can be active
energy consumed with code 129 (type b).