51
CVM
k
2
CONFIGURATION
Edit the two digits in the equation that correspond to the appropriate alarm(s). Between the two
digits corresponding to the alarm, an "*" or "+" sign can be entered. These correspond to the
AND or OR functions, respectively, and will be applied between the alarms congured.
4.7.2.3. Digital inputs conguration
The card inputs are also congured in two different ways depending on whether the user
desires to congure the input as an incremental counter or a two-state logic input (ON/OFF).
size = 0000
By setting the input size to zero, the input will be congured for ON/OFF input status. When
the input is congured as Boolean, it is not necessary to congure the next menu option, Dec.
pos.
size ≠ 0000
When an input size other than zero is congured, this is congured as an incremental pulse
counter, which can have a maximum counter value of 10M. The value to enter is the multiplier
for each input pulse.
Dec. pos: Indicate the decimal positions that the corresponding input counter should have.
The options available in the lower menu include:
Next(F2). This increases the input number from 1 to a maximum of 08 to access its
conguration. From the 08 input conguration screen, pressing F2 (Next) again
will take the user back to the 01 input conguration screen.
OUT (F1): Press this button to access the alarms conguration screen, Section 4.7.2.1.
To store the modied parameters in memory, press SET and conrm with OK (F4). To exit without
saving changes press ESC (F3).